Equivalent circuit of single phase transformer pdf

Equivalent circuit, phasor diagram, open circuit and short circuit tests, regulation and efficiency topic of electrical machines subject in previous gate papers. Let, r 1 is the resistance of the primary winding and r 2 is the resistance the secondary winding which is shown in the figure. The connection diagram for the short circuit test on the transformer is shown in the figure below. This assumption allows the decomposition of the equivalent resistance and reactance into the primary and secondary components. Equivalent circuit of transformer referred to primary side and secondary side. Tests on a single phase transformer objectives to determine the parameters of the equivalent circuit, efficiency and voltage regulation of the given transformer by open circuit test and short circuit test. Steps to drawing the equivalent circuit diagram for a single phase transformer. The equivalent circuit diagram of transformer is given below. Equivalent circuit of transformer referred to primary and secondary side.

Equivalent circuit of transformer referred to primary and. Equivalent circuit model of a single phase of transformer. Equivalent circuit of transformer referred to primary. Equivalent circuit diagram of a transformer is basically a diagram which can be resolved into an equivalent circuit in which the resistance and leakage reactance of the transformer are imagined to be external to the winding. The single phase supply requires more maintenance and become costly as compared to three phase supply. Calculate transformer voltage regulation and efficiency. Thus the complete phasor diagram of transformer at no load will be as shown below. Equivalent circuit of a single phase induction motor the equivalent circuit of a single phase induction motor can be obtained by two methods named as the double revolving field theory and cross field theory. The equivalent circuit of single phase transformer is further simplified by transferring all the quantities to either primary or secondary side.

Hence, the function of windings, thereafter, will only be the transforming the voltage. A singlephase transformer consists of primary and secondary winding. Recently, an increasing concern has been raised about turntoturn faults ttfs in power transformers, because these faults can lead to severe transformer insulation failure and consequently, its outage. A single phase, 100 mva, 20080 kv transformer has the following test data. When the transformer secondary is connected to an inductive load, the current flowing in the secondary winding is lagging w. Use kfactorrated transformer to solve nonlinear load problems. The equivalent circuit of a singlephase transformer. Martinez, member, ieee abstractan equivalent circuit for the leakage inductance of threewinding transformers is presented. Transformer equivalent circuit electrical concepts. In a transformer, primary and secondary windings have some resistance. The connection diagram for short circuit test on transformer is shown in the figure.

The determination of electrical equivalent circuit parameters of a single phase power transformer from open circuit and short circuit tests. Because the three phase supply requires less conductor as compared to single phase supply for the equivalent circuit. A second transformer has a core with all its linear dimensions 2 times the corresponding dimensions of the first transformer. The single phase supply is mostly used in the house and for running the small loads. Hence, it is seen that the short circuit test gives copper losses of transformer and approximate equivalent resistance and reactance of the transformer. For this transformer, the open circuit voltage is 23. Transformer open circuit test in the open circuit test, the transformer rated voltage is applied to the lowvoltage side of the transformer with the highvoltage side left open. Video lecture on open circuit test and short circuit test on transformer of chapter single phase transformer of subject basic electrical engineering for firstyear engineering students. Static finite element solutions are used to determine the electrical equivalent circuit parameters of a singlephase transformer with different number of winding turns in the primary and secondary. The individual components shown in the diagram have the following. In this lab you will develop the equivalent circuit of a single phase transformer. Explain the four standard threephase transformer configurations 2. The equivalent model of a real transformer is as follows.

Determination of transformer equivalent circuit parameters. Soman fundamental theory of a transformer equivalent circuit performance of transformer single phase transformer prof s. A voltmeter, wattmeter, and an ammeter are connected in hv side of the transformer as shown. The equivalent circuit of a transformer consists of a combination of resistance, inductance, capacitance, voltage etc. Another approach to solve circuits containing transformers is the perunit system. Two simple tests are used to determine the values for the parameters of the transformer equivalent circuit.

Equivalent impedance of transformer is essential to be calculated because the electrical power transformer is an electrical power system equipment for estimating different parameters of the electrical power system which may be required to calculate the total internal impedance of an electrical power transformer, viewing from primary side or secondary side as. In fact equivalent circuit of any electrical device is necessary for its performance analysis and to find any scope of further design modification. Jun 04, 2018 important points for phasor diagram of transformer. Firstly the equivalent circuit is developed on the basis of double revolving field theory when only its main winding is energized. Open circuit and short circuit test on transformer. Single phase transformers accept single phase ac power and output single phase ac power, typically at a higher or lower voltage level. Sketch the appropriate perunit equivalent circuit for the 8000240 v, 60 hz, 20 kva transformer with r c 159 k, x m 38. From the above transformer tests, it can be seen that cu loss of a transformer depends on current, and iron loss depends on voltage.

To conduct standard open and short circuit tests in order to. The equivalent circuit of a single phase transformer. Singlephase equivalent circuit an overview sciencedirect. This transformer is operated in the stepdown mode and delivers 75% of its rated power to a load that has a power factor of 0. Slideshare uses cookies to improve functionality and performance, and to provide you with relevant advertising. Equivalent impedance of transformer is essential to be calculated because the electrical power transformer is an electrical power system equipment for estimating different parameters of the electrical power system which may be required to calculate the total internal impedance of an electrical power transformer, viewing. This ppt covers the operating principle,its construction,equivalent circuit and efficiency of a single phase transformer.

Equivalent circuit of a single phase induction motor. Single phase transformers selection guide engineering360. Construction of single phase transformer javatpoint. Resistances and reactances of transformer, which are described above, can be imagined separately from the windings as shown in the figure below. Transformers are critical for providing electrical isolation which is necessary for the safe operation of. The single phase is used in a place where less power is required and for running the small loads. The primary is connected with a 3phase line with lineline voltage vs. In this case, the magnetizing impedance is assumed to be much larger than the secondary resistance and. Apr 25, 2014 the transformers equivalent circuit to model a real transformer accurately, we need to account for the following losses.

Open circuit test and short circuit test on transformer. The classical equivalent circuit of a single phase transformer or a single phase representation of a threephase transformer is used in the experiment figure 2 5. A single phase 10 kva, 50 hz transformer with 1 kv primary winding draws 0. Now, we can easily prove that the resistance of two winding can be transferred to any one of the two windings of the transformer. Single phase emf generation, average and effective values of sinusoids, j operations, complex representation of impedances, phasor diagrams, power factor, power in complex notation, solution of series and parallel circuits. Power transformer open and short circuit tests objectives. To convert the transformer to perunit system, the primary circuit base. So were asked to draw the equivalent single phase circuit of. Single phase transformers are used in power supplies and other equipment to convert ac voltages and currents from one value to another. Energy is transferred from one circuit to one or more circuits via electromagnetic induction. Electrical power transformer is a static device which transforms electrical energy from one circuit to another without any direct electrical connection and with the help of mutual induction between two windings. These laminations are provided in the transformer to reduce eddycurrent loss, and the silicon steel reduces hysteresis loss. Develop transformer equivalent circuits from opencircuit and short circuit test data.

From these measurements, the core loss resistance, r c, and mutual reactance, x m, can be calculated as 234. Open and short circuit test of transformer electrical4u. Let us assume that the current is lagging by an angle of. These equivalent circuits can be simply simulated in any. Equivalent circuit of transformer resistances and reactances of transformer, which are described above, can be imagined separately from the windings as shown in the figure below. The core of the transformer is made of thin sheets called laminations of high grade of silicon. The classical equivalent circuit of a singlephase transformer or a singlephase representation of a threephase transformer is used in the experiment figure 2 5. A low voltage of around 510% is applied to that hv side with the help of a variac i. This is done in order to make the calculations easy. Approximate equivalent circuit a and b if it is desired to find the parameters of the exact equivalent circuit of fig. Explain the four standard three phase transformer configurations.

Equivalent circuit diagram of single phase transformer. The modern heuristic search technique, bacterial foraging algorithm has been used to determine the equivalent circuit parameters. Parameter estimation of single phase core type transformer. Transformer equivalent circuit transformer electrical. Equivalent circuit of transformer your electrical guide. We should resolve the stationary pulsating magnetic field into two rotating fields. R1, x1, r2, x2 being the copper resistancereactance of the primary and secondary. This will be accomplished through a short circuit and open circuit test.

Exact equivalent circuit model of a single phase transformer. Equivalent circuit of transformer problem 1 single phase transformer duration. Total 15 questions have been asked from single phase transformer. Open circuit test and short circuit test on transformer are very economical and convenient because they are performed without actually loading of. Soman visiting faculty department of electrical and computer engineering virginia tech email protected department of electrical engineering iitbombay september 11, 2012 prof s. Electrical machines for mechatronics laboratory 2 5 from this information, its possible to determine the power factor of the input current and therefore both the magnitude and the angle of the excitation impedance. Determination of parameters of an equivalent circuit of a. Equivalent circuit model for a single phase transformer. Pdf a single phase transformer equivalent circuit for. Open circuit and short circuit tests on single phase transformer 1 aim to understand the basic working principle of a transformer. The equivalent circuit of the singlephase differs than of the threephase because the single phase motor circuit is given by double revolving field theory. Singlephase transformers 3 measuring leakage reactances if the secondary of the transformer is shortcircuited, the magnetizing current i. In this paper, two simplified and accurate equivalent circuits of single phase, two winding transformer under ttf condition are proposed.

The model is derived from the principle of duality between electric and magnetic. Aug 05, 2016 video lecture on open circuit test and short circuit test on transformer of chapter single phase transformer of subject basic electrical engineering for firstyear engineering students. The two tests are the shortcircuit and opencircuit tests. Equivalent circuit diagram of a transformer is basically a diagram which can be resolved into an equivalent circuit in which the resistance and leakage reactance. Jun 05, 2018 transformer equivalent circuit is the electrical circuit representation of equations describing the behavior of transformer. The primary is connected with a 3 phase line with lineline voltage vs. The equivalent circuit of a real transformer at low frequency 7.

Ece 494 electrical engineering laboratory iii lab 3. Therefore it is seen that the open circuit test on transformer is used to determine core losses in transformer and parameters of the shunt branch of the equivalent circuit of the transformer. Static finite element solutions are used to determine the electrical equivalent circuit parameters of a single phase transformer with different number of winding turns in the primary and secondary. In order for a model to be useful, there must be a way to determine the values of the model parameters. A 100 kva, 7200 480 v 60 hz single phase transformer has the following parameters all given in ohms. Equivalent circuit of induction motor for 3 phase and. Develop transformer equivalent circuits from opencircuit and shortcircuit test data. Impedance and voltagelevel conversions are avoided. A single phase transformer is a type of power transformer that utilizes. Singlephase equivalentcircuit modelfollowing the method described in section 3. Also, machine and transformer impedances fall within fairly narrow ranges for each type and construction of device while the perunit system is employed.

1365 666 645 1605 594 394 471 801 228 299 421 1371 1558 1432 1294 1209 538 1280 1577 176 319 243 1198 1186 1255 778 708 840 1034 1237 257 634